Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
2.
J Interv Cardiol ; 2024: 5524668, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38352195

RESUMEN

Background: Ventricular electrical storm (VES) is characterized by the occurrence of multiple episodes of sustained ventricular arrhythmias (VA) over a short period of time. Radiofrequency ablation (RFA) has been reported as an effective treatment in patients with ventricular tachycardia (VT). Objective: The aim of the present study was to indicate the short-term and long-term predictors of recurrent VA after RFA was performed due to VES. Methods: A retrospective, single-centre study included patients, who had undergone RFA due to VT between 2012 and 2021. In terms of the short-term (at the end of RFA) effectiveness of RFA, the following scenarios were distinguished: complete success: inability to induce any VT; partial success: absence of clinical VT; failure: inducible clinical VT. In terms of the long-term (12 months) effectiveness of RFA, the following scenarios were distinguished: effective ablation: no recurrence of any VT; partially successful ablation: VT recurrence; ineffective ablation: VES recurrence. Results: The study included 62 patients. Complete short-term RFA success was obtained in 77.4% of patients. The estimated cumulative VT-free survival and VES-free survival were, respectively, 28% and 33% at the 12-month follow-up. Ischemic cardiomyopathy and complete short-term RFA success were predictors of long-term RFA efficacy. Neutrophil to lymphocyte ratio (NLR) and GFR <60 mL/min/1.73 m2 were associated with VES recurrence. NLR ≥2.95 predicted VT and/or VES recurrence with a sensitivity of 66.7% and specificity of 72.2%. Conclusion: Ischemic cardiomyopathy and short-term complete success of RFA were predictors of no VES recurrence during the 12-month follow-up, while NLR and GFR <60 ml/min/1.73 m2 were associated with VES relapse.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Taquicardia Ventricular/cirugía , Ablación por Catéter/efectos adversos , Cardiomiopatías/etiología , Cardiomiopatías/cirugía , Recurrencia
3.
Diagnostics (Basel) ; 14(2)2024 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-38248011

RESUMEN

During the diagnostic work-up in oncology, it is exceedingly rare to assume a concomitant presence of two cancers, a benign one and a malignant one, in a single patient. A 61-year-old man was admitted to the cardiology department for cardiac evaluation prior to planned radical treatment of non-small cell (NSCLC) left lung cancer (cT3N1M0). Echocardiography revealed a prominent, unpedunculated structure, measuring 17 × 14 mm, located in the left atrium (LA) near the fossa ovalis. The tumor was confirmed via cardiac magnetic resonance (CMR) imaging, which showed the radiological features of an atrial myxoma. The patient consulted with the Cardiac Surgery Department and was deemed ineligible for surgical treatment of a lesion with mucinous features; thus, no definitive histopathologic confirmation of the tumor present was possible. He was then successfully treated with radical radiochemotherapy and immunotherapy. During the 2-year follow-up, regular echocardiography and CMR were performed, which documented a stable LA tumor size.

5.
Cancers (Basel) ; 15(24)2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38136269

RESUMEN

Cardio-oncology currently faces one of the greatest challenges in the field of health care. The main goal of this discipline is to ensure that patients treated for cancer do not suffer or die from cardiovascular disease. The number of studies on the mechanisms of heart injury during cancer treatment is constantly increasing. However, there is insufficient data on heart rhythm disorders that may result from this treatment. This issue seems to be particularly important in patients with lung cancer, in whom anticancer therapy, especially radiotherapy, may contribute to the onset of cardiac arrhythmias. The observed relationship between cardiac dosimetry and radiotherapy-induced cardiotoxicity in lung cancer treatment may explain the increased mortality from cardiovascular causes in patients after chest irradiation. Further research is essential to elucidate the role of cardiac arrhythmias in this context. Conversely, recent reports have highlighted the application of stereotactic arrhythmia radioablation (STAR) in the treatment of ventricular tachycardia. This review of available studies on the epidemiology, pathogenesis, diagnosis, and treatment of arrhythmias in patients treated for lung cancer aims to draw attention to the need for regular cardiological monitoring in this group of patients. Improving cardiac care for patients with lung cancer has the potential to enhance their overall therapeutic outcomes.

7.
Front Cardiovasc Med ; 10: 1230417, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547245

RESUMEN

A 25-year-old female with idiopathic pulmonary arterial hypertension (PAH), who had a Hickman catheter implanted for continuous intravenous epoprostenol infusion, was admitted to the clinic after inadvertently cutting the catheter with nail scissors during a routine dressing change. Approximately 7 cm of the external segment of the Hickman catheter remained intact, with the distal end knotted by paramedics. A decision was made to repair the damaged Hickman catheter. However, it was discovered that its lumen was completely occluded by thrombosis. Therefore, catheter patency was mechanically restored using a 0.035-inch stiff guidewire in a sterile operating theatre setting, under fluoroscopy guidance. Successful aspiration and catheter flushing were achieved. Continuity of the Hickman catheter was then restored using a repair kit (Bard Access Systems) as per the manufacturer's instructions, with no visible leakage thereafter. Epoprostenol infusion through the Hickman catheter was resumed 24 h later, and the patient was discharged in good general condition two days afterward.

8.
Front Cardiovasc Med ; 10: 1171541, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37502188

RESUMEN

A 28-year-old female patient diagnosed with Ehlers-Danlos syndrome type III (hypermobile EDS, hEDS) was admitted to the cardiology clinic due to a 3-year history of symptomatic ventricular arrhythmia in the form of multiple premature ventricular contractions (PVCs). Attempts at antiarrhythmic treatment with beta-blockers, propafenone, and verapamil were unsuccessful. Due to the diagnosis of hEDS and the high risk of vascular complications related to the ablation procedure, invasive treatment was abandoned, and it was decided to implement flecainide. After the flecainide treatment initiation, a spectacular improvement in the number of ventricular arrhythmias was observed, along with the disappearance of the complaints previously reported by the patient. To the best of our knowledge, this is the first described case of spectacular flecainide antiarrhythmic effect in a patient with numerous PVCs also diagnosed with EDS. Flecainide treatment in the EDS group could be a successful alternative to ablation, which can lead to serious vascular and even life-threatening complications, especially after the failure of propafenone and beta-blockers treatment.

9.
J Clin Med ; 12(10)2023 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-37240533

RESUMEN

Patients treated due to mediastinal lymphomas are at risk of cardiovascular complications, as they receive chemotherapy, usually containing anthracyclines, often combined with thoracic radiotherapy. The aim of this prospective study was to assess early asymptomatic cardiac dysfunction using resting and dobutamine stress echocardiography (DSE) at least 3 years after the end of mediastinal lymphoma treatment. Two groups of patients were compared: those treated with chemoradiotherapy and those exclusively treated with chemotherapy. Left ventricular contractile reserve (LVCR) during DSE was assessed using changes in LV ejection fraction (LVEF), LV global longitudinal strain (LV GLS), and a novel parameter-Force, which is the ratio of the systolic blood pressure to the LV end-systolic volume. The study included 60 patients examined at a median of 89 months after the end of treatment. Resting echocardiography showed normal LVEF of 58.9 ± 9.6%, borderline LV GLS of -17.7 ± 3%, decreased mean stroke volume (SV) of 51.4 ± 17 mL, and indexed SV of 27.3 ± 8 mL/m2, and the right ventricular free wall longitudinal strain (LS) was impaired in some patients but not in all. There were no significant differences between the groups, with the exception of arterial hypertension, which was more common in the chemotherapy group (32% vs. 62.5%, p = 0.04). In resting echocardiography, only LV posterior wall LS differed significantly and was impaired in patients treated with chemotherapy (-19.1 ± 3.1% vs. -16.5 ± 5.1%, p = 0.04). DSE, performed in 21 patients after a median of 166 months from the end of cancer treatment, detected new contractility disorders in 1 patient (4.8%) and decreased LVCR in the majority of patients when determined using changes in LVEF or LV GLS, and in all patients when assessed with changes in Force. Conclusions: Most asymptomatic mediastinal lymphoma survivors showed preserved ventricular function on resting echocardiography. However, all of them showed impaired LV contractile reserve on DSE, as assessed with a simple parameter-Force. This may indicate subtle LV dysfunction and confirms the need for long-term monitoring of patients with potentially cardiotoxic cancer treatment.

11.
Cancers (Basel) ; 15(3)2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36765941

RESUMEN

Several therapies used in cancer treatment are potentially cardiotoxic and may cause left ventricular (LV) dysfunction and heart failure. For decades, echocardiography has been the main modality for cardiac assessment in cancer patients, and the parameter examined in the context of cardiotoxicity was the left ventricular ejection fraction (LVEF). The assessment of the global longitudinal strain (GLS) using speckle tracking echocardiography (STE) is an emerging method for detecting and quantifying subtle disturbances in the global long-axis LV systolic function. In the latest ESC guidelines on cardio-oncology, GLS is an important element in diagnosing the cardiotoxicity of oncological therapy. A relative decrease in GLS of >15% during cancer treatment is the recommended cut-off point for suspecting subclinical cardiac dysfunction. An early diagnosis of asymptomatic cardiotoxicity allows the initiation of a cardioprotective treatment and reduces the risk of interruptions or changes in the oncological treatment in the event of LVEF deterioration, which may affect survival.

13.
Materials (Basel) ; 15(24)2022 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-36556681

RESUMEN

A material strength investigation along with a detailed microfractography analysis of fractures formed during static tensile tests of steel Armstal 550 was performed. The tests in this research were conducted in a temperature range of 298 to 973 K. In addition, during tensile tests at ambient temperature, optical measurements of strain maps and the curvature of the neck were performed. The minimum cross-sectional diameter and the radius of the neck curvature during tensile tests were obtained. The data can be directly used to obtain the true stress-strain curve. The material property analysis confirmed the high strength of the Armstal 550 alloy. The ultimate strength at room temperature equals 2.14 GPa, whereas the yield point equals 1.65 GPa. A decrease in the strength parameters along with an increase in temperature was noted. This is a typical phenomenon related to a change in the density and thermal expansion of steel under the influence of the temperature increase. For example, at a temperature of 500 °C, the ultimate strength is more than 50% less than at room temperature. An in-depth analysis of the metallography and microfractography of fractures resulting from static tensile tests showed the formation of atypical nano- and microstructures with an elongated shape. Local nano- and microstructures were observed at different levels of intensity for different temperatures. The largest clusters of nanoparticles were present on the surfaces of the specimens examined at a temperature of 973 K. Scanning microscopy analysis confirmed the presence of molybdenum oxides.

14.
Front Cardiovasc Med ; 9: 985421, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36419494

RESUMEN

Cardiac arrhythmias occurring during pregnancy pose a therapeutic problem as antiarrhythmic drugs can be potentially harmful to the fetus. A 35-years-old woman in the 20th week of pregnancy was admitted to the Department of Cardiology due to the first episode of arrhythmia in her life. During the event, the patient was wearing an Apple Watch Series 6, which records a 30-sec single-channel ECG. The recording showed narrow QRS complex tachycardia of 216 bpm, and short RP interval and atrioventricular nodal reentrant tachycardia (AVNRT) was recognized. Due to the mild nature of the arrhythmia, antiarrhythmic pharmacotherapy was not initiated. The use of mobile health (mHealth) devices such as wearables and health monitoring applications is now a valuable addition to routine cardiac diagnostics for patients of all ages and levels of cardiovascular risk.

15.
Kardiol Pol ; 80(12): 1231-1237, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36052564

RESUMEN

BACKGROUND: A concomitant use of a pacemaker and a subcutaneous implantable cardioverter-de-fibrillator (S-ICD) may be required in some patients. AIMS: Our study aimed to evaluate the influence of permanent cardiac pacing on the morphology of the QRS complex in the context of S-ICD screening. METHODS: One hundred patients with cardiac electronic implantable devices (CIEDs) were included in whom S-ICD screening could be performed both during intrinsic and paced rhythm. RESULTS: The positive result of screening during spontaneous rhythm for at least one vector (in both supine and standing positions) was obtained in 80% and for 2 vectors in 59% of patients. Positive screening during paced rhythm for at least one vector was recorded in 36% of patients (78% right ventricular and 22% biventricular pacing) and for 2 vectors in 15% of patients (93% right ventricular and 7% biventricular pacing). At least one vector acceptable during both types of rhythm and in both positions was recorded in 23% of patients and at least 2 vectors in 8% of patients. CONCLUSIONS: The use of S-ICD in patients with paced ventricular rhythm is associated with a serious risk of inappropriate sensing due to different QRS morphology during intrinsic and paced rhythm, and it is particularly high in patients in whom periods of spontaneous rhythm interchange with periods of ventricular pacing. That risk has been hardly acknowledged in available reports, but according to our data, it is significant, and therefore it should be considered during S-ICD screening.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Electrocardiografía , Muerte Súbita Cardíaca/prevención & control , Fibrilación Ventricular
18.
Materials (Basel) ; 15(16)2022 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-36013877

RESUMEN

The aim of this study is the analysis of the multiple pelvis fracture mechanism in side-impact dynamic load cases. The elaborated numerical model of a pelvis complex includes pelvic and sacral bones as well as soft tissues such as ligaments and cartilages. The bone has been modelled as a viscoelasticity material based on the Johnson-Cook model. The model parameters have been chosen based on the experimental data. The uniqueness of a presented approach refers to the selection of crack criteria for the bone. Thus, it was allowed to analyse the process of multiple fractures inside the pelvic bones. The analysis was evaluated for the model in which the deformation rate influences the bone material properties. As a result, the stress distributions inside particular bones were changed. It has been estimated that the results can vary by 50% or even more depending on the type of boundary conditions adopted. The second step of work was a numerical analysis of military vehicle subjected to an IED. An analysis of the impactor's impact on the pelvis of the Hybrid ES-2RE mannequin was conducted. It was shown that the force in the pelvis exceeds the critical value by a factor of 10. The results of the numerical analysis were then used to validate the model of a military vehicle with a soldier. It was shown that for the adopted loading conditions, the critical value of the force in the pelvis was not exceeded.

20.
Front Bioeng Biotechnol ; 9: 725006, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34869249

RESUMEN

Attacks with improvised explosive device (IED) constituted the main threat to, for example, Polish soldiers in Iraq and Afghanistan. Improving safety during transport in an armored vehicle has become an important issue. The main purpose of the presented research is to investigate the mechanism of lower leg injuries during explosion under an armored vehicle. Using a numerical anatomic model of the lower leg, the analysis of the leg position was carried out. In all presented positions, the stress limit of 160 (MPa) was reached, which indicates bone damage. There is a difference in stress distribution in anatomic elements pointing to different injury mechanisms.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...